• Software Downloads
  • Log In
Entropic-logoEntropic-logo-stickyOfficial Entropic Logo 2025Entropic-logo-sticky
  • About
    • Careers
  • Solutions
    • Commercial
      • A-Class Office
      • Commercial Kitchens
      • Education
      • Hotels & Leisure
    • Industry
      • Cleanroom
      • Data Centres
      • Industrial
      • Public Spaces
      • Laboratory
    • Health
      • Healthcare
      • Laboratory
      • Operating Theatre
    • Residential
      • Apartment Block
      • Home Ventilation
      • Student Accommodation
    • Services
      • Fire Safety
      • Maintenance & Commissioning
  • Products
    • Air Handling Units
    • Air Sterilisation Units for Hygienic Healthy Air
    • Atex Products
    • Balancing Dampers
    • Chilled Beams
    • Chillers
    • Diffusers and Terminal Units
    • Duct Mounted Equipment
    • External Louvres
    • Fan Coil Units
    • Fire Dampers
    • Fire Damper Controls
    • GMP Warehouse Diffusers
    • Heatpumps
    • Heat Recovery Units (HRV)
    • HEPA Terminals
    • Kitchen Ventilation and Odour Reduction
    • Laboratory Ventilation
    • Measuring Grids
    • Operating Theatre System
    • Pressure Relief & Non-return Dampers
    • Radiant Panels and Acoustic Panels
    • Smoke Control Dampers & Smoke Evacuation Dampers
    • Stainless Steel Products
    • VAV Dampers
    • Latest Products
    • By Building
      • A-class Offices
      • Commercial Kitchens
      • Data Centres
      • Healthcare
      • Domestic Ventilation
      • Hotel
      • Laboratory Ventilation
  • Case Studies
    • By Project Type
      • A-Class Office
      • Cleanroom
      • Commercial Kitchens
      • Data Centres
      • Education
      • Fire Safety
      • Healthcare
      • Hotels & Leisure
      • Industrial
      • Laboratory
      • Pharmaceutical
      • Public Spaces
    • By System & Product
      • AHUs
      • Chilled Beams
      • Chillers
      • Diffusers
      • Louvres
      • Fan Coil Units
      • Radiant Panels
    • Reference Sites
      • Reference Sites Maps
  • Resources
    • Software
      • Software Downloads
      • Revit plugin for BIM
    • Design Guide
      • Design guides and Guidance Documents
      • Green Building Design
      • For discussion
      • White Paper
    • Media
      • News
      • Videos
    • CPD Training
      • Book a CPD/ Training
    • Testimonials
      • Clients Testimonials
  • Contact
  • About
    • Careers
  • Solutions
    • Commercial
      • A-Class Office
      • Commercial Kitchens
      • Education
      • Hotels & Leisure
    • Industry
      • Cleanroom
      • Data Centres
      • Industrial
      • Public Spaces
      • Laboratory
    • Health
      • Healthcare
      • Laboratory
      • Operating Theatre
    • Residential
      • Apartment Block
      • Home Ventilation
      • Student Accommodation
    • Services
      • Fire Safety
      • Maintenance & Commissioning
  • Products
    • Air Handling Units
    • Air Sterilisation Units for Hygienic Healthy Air
    • Atex Products
    • Balancing Dampers
    • Chilled Beams
    • Chillers
    • Diffusers and Terminal Units
    • Duct Mounted Equipment
    • External Louvres
    • Fan Coil Units
    • Fire Dampers
    • Fire Damper Controls
    • GMP Warehouse Diffusers
    • Heatpumps
    • Heat Recovery Units (HRV)
    • HEPA Terminals
    • Kitchen Ventilation and Odour Reduction
    • Laboratory Ventilation
    • Measuring Grids
    • Operating Theatre System
    • Pressure Relief & Non-return Dampers
    • Radiant Panels and Acoustic Panels
    • Smoke Control Dampers & Smoke Evacuation Dampers
    • Stainless Steel Products
    • VAV Dampers
    • Latest Products
    • By Building
      • A-class Offices
      • Commercial Kitchens
      • Data Centres
      • Healthcare
      • Domestic Ventilation
      • Hotel
      • Laboratory Ventilation
  • Case Studies
    • By Project Type
      • A-Class Office
      • Cleanroom
      • Commercial Kitchens
      • Data Centres
      • Education
      • Fire Safety
      • Healthcare
      • Hotels & Leisure
      • Industrial
      • Laboratory
      • Pharmaceutical
      • Public Spaces
    • By System & Product
      • AHUs
      • Chilled Beams
      • Chillers
      • Diffusers
      • Louvres
      • Fan Coil Units
      • Radiant Panels
    • Reference Sites
      • Reference Sites Maps
  • Resources
    • Software
      • Software Downloads
      • Revit plugin for BIM
    • Design Guide
      • Design guides and Guidance Documents
      • Green Building Design
      • For discussion
      • White Paper
    • Media
      • News
      • Videos
    • CPD Training
      • Book a CPD/ Training
    • Testimonials
      • Clients Testimonials
  • Contact

Air Handling Units Eco design

  • Home
  • Green Buildings
  • Air Handling Units Eco design

Air Handling Units Eco design

Is Ecodesign applicable to all Air Handling Units?

You need to ask yourself these two questions:

  1. Is the unit serving areas of the building designed for/foresees human occupancy?

If yes, the unit must comply with Ecodesign.

  1. Is the unit designed to replace utilized air with a minimum of 10% outdoor air.

If yes, the unit must comply with Ecodesign.

What is the spirit of Ecodesign?

The spirit of Ecodesign is to reduce the energy use of buildings without compromising the indoor comfort and air quality while at the same time allowing existing maintenance schedules to continue. This directive allows for the EU to set regulations to ensure that environmental targets can be met.

AHU Ecodesign directive EU 1253-2014
What does this mean for Air Handling Units?

To comply with Ecodesign 2018 in general AHUs need to be more efficient:

  • Heat recovery system (HRS) – Minimum thermal efficiency of 73% for plate heat exchangers (PHEX) & thermal wheels (TW). 68% for run around coils (RAC). All HRS shall have a thermal bypass. A traditional mix box with recirculation damper is not considered a method of heat recovery according to Ecodesign.

What does this mean for Air Handling Units?

  • Fan & Motor – Must be equipped with a multi or variable speed drive and minimum fan efficiency must be met.
  • Internal specific fan power (SFPint) – Maximum SFPint is calculated for each individual unit based on the performance of the selected components.
  • Filters – must be equipped with a visual signal or alarm when filter exceeds final pressure.

To check our Air Handling Units (AHUs) products click here

Share

Related posts

Typical components of a Modular AHU

November 26, 2019

Inside a Custom Modular Air Handling Unit (AHU)


Read more
October 17, 2019

Data Centre air handling units (AHUs) typical features


Read more
July 25, 2019

EN 378 Guide


Read more

Comments are closed.

Sign up to our Newsletter & Software Updates


  • This field is for validation purposes and should be left unchanged.

Entropic Ireland

Entropic Ltd

Unit F3, Maynooth Business Campus,
Maynooth, Co. Kildare,
W23 K7N3
IRELAND

Phone: +353 1 6106170

Email: info@entropic.ie

 

 

 

Entropic UK

Entropic Ecology Indoors UK Ltd

Holden House,
57 Rathbone Place,
London, W1T 1JU
UK

Phone: +44 20 7126 8310

Email: info@entropic.co.uk
 

My Account

Login

My Downloads

Privacy Policy

Terms & Conditions

© 2025 Entropic. All Rights Reserved
  • Software Downloads